USMXUKDEFRESITRU
Cf.example.1

For combined walls (pipes) with cold formed sheet piles

fits

  • cold formed

works with

SKL-9, 10, 12
SKS-11, 13, 14, 16
SKZ-20, 22, 23, 24
SCZ-14, 16, 18, 19, 20, 21, 22, 23, 25, 26, 29, 30
XZ-85, 95

steel grade
ASTM Grade 50 or better,
MARINER™ steel
weight
~ 7.46 lb/ft

Need To Build a Combined Wall?

The Combined Sheet Pile Tool on iSheetPile.com can help.


Installation

  1. The pipes are delivered with the connectors already attached.
  2. First, install the king piles (pipes) as you would in any combined sheet pile wall application.
  3. Grasp the sheet piling and thread between the already installed pipe piles.
  4. Increase flexibility in the middle interlocks of the sheet piles, combined with the swing of the connectors, to enable easier threading of the intermediate sheet piling.
  5. All welding seams are a minimum ~6mm (~0.25”).
  6. Both sides have a continuous minimum tip and toe welding of ~500mm (~20”).
  7. Both sides are tack welded in the free length between tip and toe welding with 200mm/m (8”/yd). The distance from seam to seam is ~800mm (~31.5”) or less.
  8. In salt water, the water side is continuously welded on the whole pile length. Follow the instructions above for the reverse side of the pile, if it is not in contact with salt water.

PilePro® connectors are exclusively supplied through PilePro Steel, LP.
866-666-7453 / 512-243-1228 | info@pilepro.com